The Flooring Expert

1000 Grease Distributor Progressive Metering Devices Use For Excavator Lubrication System

Short Description:

Distribution ElementThe distribution element is used to automatically distribute the lubricant to each lubrication point according to the set dosage.Our company mainly produces distribution components: chip type progressive distributor, integral type progressive distributor, double line distributor and oil injector.The progressive distributor can output a certain amount of lubricant from the oil outlet to each lubricating point in the specified order. The oil outlet is stable and reliable, the structure is compact, the installation is simple, and the working state of the distributor can be monitored. The feed distributor can be divided into plate type, modular type and integral type in structure, and different distributor combinations can be selected according to actual working conditions. The progressive Distributor shall not block any oil outlet. If the oil outlet is blocked, the whole set of distributors will not discharge oil.1000 / 2000 / 3000 Type Progressive DistributorThe progressive distributor is composed of a head piece, a tail piece and several working pieces. Through the continuous action of the plunger in the working piece, oil is supplied to each lubricating point point point by point. Each working piece has 2 oil outlets, and usually a group of distributors has 3-10 working pieces. The chip type progressive distributor is applicable to the working conditions of high pressure and wide temperature changes. The oil outlet is stable and reliable. The oil outlet can be equipped with a circulation indicator to monitor the working state of the distributor.


Product Detail

Product Tags

Use For Progressive Lubrication System(PRG)
Progressive lubrication systems consist of a lubricator, progressive distributors, pipeline accessories and controllers. Features include: accurate metering of volume depending on piston diameter and stroke, easy installation, adjustment and maintenance. The PRG system is widely used in mining, steel mills, metallurgy, vehicles, harbors, construction machinery and other industries. The lubricant used is from NLGI-000 toNLGI-2, while system pressure ranges from 20 to 45Mpa. The filter element is 150μ.The progressive distributor is divided into two kinds of distributors: a center progressive distributor and a model progressive distributor. There is a choice of segment combinations, effectively ranging from periodic to near continuous lubrication.
Advantages: Precise discharge – All points can be fed and monitor individually – Trouble free installation – Easily pinpoints system issues

1- The 1000/2000/3000 series distributors distribute and proportion incoming oil or grease to bearing points. A typical 100 distributor consists of an inlet section, three to nine valves and an end section. One assembly can serve up to a maximum of 18 lubrication points.
2- The 1000/2000/3000 Series distributors have a sliding discharge piston and built-in outlet check valves. Blocks are offered in three output sizes. The discharge capacity of a block is determined by varying the piston diameter in the valve block. Valve blocks have two outlets located at each end of the assembly (double outlet blocks). They supply rated discharge outputs from each of the two outlets during one complete valve cycle. 
3- 1000 progressive grease distributor is an advanced design and reasonable structural oil distributor; Can be used in high pressure and wide temperature change conditions. It can be combined with electric and pneumatic pumps to form a single line lubrication system. It is used as a female distributor for various large machine tools and port of equipment , or for large single-line lubrication systems.

4- A standard set of dispensers consists of a “firt chip”✚a piece of “tail chip” ✚ 3-10 piece. It can provides 3-20 lubrication points for lubrication. Double outlet working chip, (after size use T to indicate the double outlet), there are two oil outlets, at the two ends of the working chip;

5- Note that for the double outlet working chip, can not Block any oil outlet, which will affect its normal operation and damage the distributor . Single grease outlet working chip (after the specification value of ,use S to indicate the single grease outlet), there is an oil outlet, which can be any of end of the working piece, and the other end of the outlet oil needs to be blocked.

1000 Metering Devices

Working chips  Standard flow ML/CYC Each chip outlet quantity  
1000-05T 0.08 2
1000-05S 0.16 1
1000-10T 0.16 2
1000-10S 0.32 1
1000-15T 0.24 2
1000-15S 0.48 1

1000 Type The main technical parameters

Max Presssure Mpa  Inlet size  Outlet size  Working chip size (mm) Install hole distance (mm) Install thread Length A  Outlet Pipe dia  (mm)  Working temperature: 
25Mpa  M10*1  /NPT 1/8  M10*1  /NPT 1/8 54*32*14 18 3-M5 A=32+N*14 Standard 6mm  -20°C to +60°C
N Chip number 

Max work pressure:25MPa

Delivery:0.08ml/cyc ~ 0.48ml/cyc
Lubricant viscosity (under standard temperature): oil≥N68,grease:NLGI 000#~2# Work temperature:-20°C~+60°C
Max work frequency (with stem):60cyc/min Max work frequency (without stem):200cyc/min Manifold number:3~8
Tubing: Outlet: Φ6mm length: 0.5~2.5m ,Inlet: Φ6mm length:1.2~3.5m

2000 Metering Devices

Working chips  Standard flow ML/CYC Each chip outlet quantity  
2000-10T 0.16 2
2000-10S 0.32 1
2000-15T 0.24 2
2000-15S 0.48 1
2000-20T 0.32 2
2000-20S 0.64 1
2000-25T 0.40  2
2000-25S 0.80  1
2000-30T 0.48 2
2000-30S 0.96 1
2000-35T 0.56 2
2000-35S 1.12 1

2000 Type The main technical parameters

Max Presssure Mpa  Inlet size  Outlet size  Working chip size (mm) Install hole distance (mm) Install thread Length A  Outlet Pipe dia  (mm)  Working temperature: 
25Mpa  M12*1 .25  M10*1  /NPT 1/8 80*45*19 32 4-M6 A=43+N*20.5 Standard 6mm  -20°C to +60°C
N Chip number 

Max work pressure:25MPa
Delivery:0.16ml/cyc ~ 1.12ml/cyc
Lubricant viscosity (under standard temperature) : oil ≥ N68, grease: NLGI 000#~2# Work temperature: -20°C~+60°C
Max work frequency (with stem): 60cyc/min Max work frequency (without stem): 200cyc/min Manifold number: 3~10
Tubing: Outlet: Φ6mm length: 1.2~3.5m
Inlet: Φ8mm length:1.5~4.5m Manifold Material: carbon steel

3000 Metering Devices

Working chips  Standard flow ML/CYC Each chip outlet quantity  
3000-25T 0.4 2
3000-25S 0.8 1
3000-50T 0.8 2
3000-50S 1.6 1
3000-75T 1.2 2
3000-75S 2.4 1
3000-100T 1.60  2
3000-100S 3.20  1
3000-125T 2 2
3000-125S 4 1
3000-150T 2.4 2
3000-150S 4.8 1

3000 Type The main technical parameters

Max Presssure Mpa  Inlet size  Outlet size  Working chip size (mm) Install hole distance (mm) Install thread Length A  Outlet Pipe dia  (mm)  Working temperature: 
25Mpa  Rp3/8  Rp1/4 128*70*28 47.6 4-M8 A=57.4+N*28.8 Standard 8mm  -20°C to +60°C
N Chip number 

Max work pressure:25MPa
Delivery:0.4ml/cyc ~ 4.8ml/cyc
Lubricant viscosity (under standard temperature) : oil ≥ N68, grease: NLGI 000#~2# Work temperature: -20°C~+60°C
Max work frequency (with stem): 60cyc/min Max work frequency (without stem): 200cyc/min Manifold number: 3~10
Tubing: Outlet: Φ8mm length: 1.5~4.5m
Inlet: Φ10mm length:1.8~5.5m Manifold Material: carbon steel