The Flooring Expert

Solar Inverter (off grid) MPPT controller

Short Description:


Product Detail

Product Tags

· ST inverter efficiency is more than 85%
· New design, adapt to wide and narrow voltage, automatically recognize frequency
· Full LED display, inverter function can be selected according to customer’s use
· 3 working modes are available: mains priority, inverter priority, energy saving mode
· More than 3 times the peak starting power, excellent load capacity
· Smart fan (automatically adjust fan speed according to internal temperature)
· Power frequency technology, pure sine wave AC output, adapt to load capacity, no-load current is smaller, more energy-saving
· Built-in AC 3-stage charging module, which can automatically adjust the charging current according to batterycapacity and actual use (5A-30A)
· It has complete battery undervoltage, overload, short circuit protection and other comprehensive protection, safe and reliable1
Model 

ST-1000

ST-1500

ST-2000

ST-3000

ST-4000

ST-5000

ST-6000

Rated Power

1000W

1500W

2000W

3000W

4000W

5000W

6000W

Peak Power

2800W

3800W

5KW

9KW

12KW

15KW

18KW

Battery Voltage

12Vdc

24Vdc

24Vdc

48Vdc

48Vdc

48Vdc

48Vdc

Working Mode

 PV(Photovoltaic priority) / AC(AC priority)optional

PV & controller  
Input Voltage Range

160

180

180

Max. Charge Current

30A

40A

40A

50A

50A

50A

60A

Max. PV input Voltage

70~200V

No Load current

≤ 5mA

Over charge protection

17V (12V); 34V (24v);  70V(48V)

Low voltage

10.2V (12V); 20.5V (24v); 41V(48V)

 Charging mode

Constant current(MPPT), constant Voltage, floating charge

Charging recovery

13.6V/27.5V/56V

Working temperature

0℃ ~40℃

Max. Conversion Efficiency

 98%

Display

LCD screen + LED lights

Mains status(Optional)  
Input Voltage Range

85VAC-140VAC/ 165VAC-265VAC

Input Frequency Range

45-65 Hz(automatically transfer to invert mode when overfrequency)

Output Voltage Range

190Vac~245Vac

Input PF.(AC/DC)

0.95

Efficiency

mains mode≥ 86%

Charge Current

10A-30A

Mains Overload

warning until decrease load

Short Circuit

yes

Inverter Output

220V±3%

Inverter Output Voltage

50 Hz / 60Hz ± 0.3Hz frequency adaptive

Output Frequency

≥0.8

Output Power Factor

linear load≤ 3%

Wave Form Distortion

4Ms typical value Max.6 Ms

PV-AC Transfer Time

invert mode≥ 85%

Efficiency

110%-130% shutdown at 30s,130%-150% shutdown at 3s  

Inverter Overload

system automatically shut down

Short Circuit

yes

Alarm  
Mains Abnormal

1time/1S, silence auto after 5S

Low Battery

1time/1S and flash battery last grid

Overload

1time/ 1S and display “overload” grid

Others  
Output Sockets

universal sockets / customized

Surge Protection

optional

Ambient Temperature

0℃ ~40℃

Ambient Humidity

10% ~90%(non condensed)(10% 90%)

Noise

≤ 50dB 


  • Previous:
  • Next:

  • Write your message here and send it to us