Product | Electromagnetic flowmeter |
Model | SUP-LDG |
Diameter nominal | DN15~DN1000 |
Nominal pressure | 0.6~4.0MPa |
Accuracy | ±0.5%,±2mm/s(flowrate<1m/s) |
Liner material | PFA,F46,Neoprene,PTFE,FEP |
Electrode material | Stainless steel SUS316, Hastelloy C, Titanium, |
Tantalum Platinum-iridium | |
Medium temperature | Integral type: -10℃~80℃ |
Split type: -25℃~180℃ | |
Power supply | 100-240VAC,50/60Hz, 22VDC—26VDC |
Ambient Temperature | -10℃~60℃ |
Electrical conductivity | Water 20μS/cm other medium 5μS/cm |
Structure type | Tegral type, split type |
Ingress protection | IP68 |
Product standard | JB/T 9248-1999 Electormagnetic Flowmeter |
Mag meter works based on Faraday’s law, and measure conductive medium with conductivity more than 5 μs/cm and flow range from 0.2 to 15 m/s. An Electromagnetic Flowmeter is a volumetric Flowmeter that measures the flow velocity of a liquid through a pipe.
The measurement principle of magnetic flowmeters can be described as follows: when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v:
E=K×B×V×D
Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow speed in cross-section of measuring tube D-Inner diameter of measuring tube |
Noted: the product strictly prohibited to be used in explosion-proof occasions.
Electromagnetic flowmeters have been used throughout industries for more than 60 years. These meters are applicable for all conductive liquids, such as:
Domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the processed neutral pulp, pulp slurry, etc
Since its establishment, our factory has been developing first world class products with adhering the principle
of quality first. Our products have gained excellent reputation in the industry and valuabletrusty among new and old customers..